Choose the right power supply

Power Supply -

Encapsulated power supplies

ECO

PoE

PoE M

NEO

NOVA

EN54

SINUS UPS

Mounting:

Wall[a]

*

*

*

*

*

*

*

*

19" rack[b]

*

*

*

*

*

*

*

*

Voltage:

9 V

*

12 V

*

*

*

*

*

*

*

*

24 V

*

*

*

*

*

*

*

48 V

*

*

230 V

*

Power outlet:

1 A

*

*

1.5 A

*

3 A

*

*

5 A

*

*

*

*

*

*

*

5.5 A

*

7 A

*

*

*

7.5 A

*

10 A

*

*

*

*

*

13 A

*

*

15 A

*

*

*

25 A

*

*

*

Effect:

25 W - 320 W

*

*

200W - 1500W

*

Batteries:

Battery

2.3 Ah - 14 Ah

7.2 Ah - 14 Ah

14 Ah - 45 Ah

14 Ah - 45 Ah

14 Ah - 45 Ah

14 Ah - 45 Ah

7.2 Ah - 45 Ah

Battery capacity[c]

60 Ah

14 Ah

225 Ah

225 Ah

225 Ah

300Ah

135 Ah

Outputs:

Load outputs

0-3

1

2

2

2

2

2

3

Communication:

To sub-central

*

*

Alarm:

Battery voltage

*

*

*

*

*

Disconnected batteries

*

*

*

*

Disconnected batteries at startup

*

*

*

*

*

Fan error

*

*

Power outage

*

*

*

*

*

*

*

Sabotage

*

*

*

*

*

Total alarm, self-test

*

System voltage

*

*

Fuse failure

*

*

*

*

*

*

Temperature alarm high/low

*

*

Undervoltage in power supply[d]

*

*

*

Aged battery

*

*

Overvoltage in power supply[e]

*

*

*

Certifications:

SSF1014

*

EN54-4 + SBF110:8

*

Annual maintenance plan:

Battery check

*

*

*

*

*

Built-in

Built-in

Fan cleaning

*

*

*

*

*

*

*

[a] See table: Enclosure for more information.

[b] See table: Enclosure for more information.

[c] Max can be specified with battery box/battery shelf, for the products that can be connected to battery box/battery shelf.

[d] Power supplies that convert 230 V to 9 V / 12 V / 24 V or 48 V cannot supply the correct voltage.

[e] Power supplies that convert 230 V to 9 V / 12 V / 24 V or 48 V cannot supply the correct voltage.

Enclosures

Table 1. Enclosures

Enclosure[a]

Wall mounting

Installation in 19" rack

Dimensions (Height x Width x Depth)

Products available in the enclosure

B2

*

127 x 71 x 61 mm

Encapsulated power supplies

B3/Mini

*

200 x 146 x 57 mm

Encapsulated power supplies

S

*

230 x 216 x 85 mm

ECO, PoE, SINUS UPS

M

*

150 × 350 × 242 mm

ECO, PoE, SINUS UPS

FLX S

*

222 x 437 x 145 mm

ECO, NEO, NOVA, PoE

FLX M

*

224 x 437 x 212 mm

EN54, NEO, NOVA, PoE, SINUS UPS

FLX L

*

444 x 437 x 212 mm

NEO, NOVA, SINUS UPS

1U

*

44 x 444 x 280 mm

EN54, Encapsulated power supplies

2U

*

88 x 444 x 280 mm

EN54

19 Rack module holder[b]

*

173 x 482 x 108 mm

Optional card, automatic fuses

MX S

*

250 x 340 x 80 mm

EN54

MX M

*

356 x 395 x 96 mm

EN54

MX L

*

455 x 356 x 187 mm

EN54

Battery Shelf M

*

215 x 438 x 200 mm

Batteries

Battery Shelf L

*

290 x 490 x 430 mm

Batteries

Battery Shelf Floor

*

130 x 448 x 500 mm

Batteries

[a] All enclosures in powder-coated sheet metal.

[b] Plexiglas door.



Optional card

Power Supply -

Encapsulated power supplies

ECO

PoE

PoE M

NEO

NOVA

EN54

SINE UPS

Insurance card:

2+2 Output module

1-2

1

1

1-4

1-4

1-4

5 Output module

1-2

1

1

1-4

1-4

1-4

6 Output modules

1

8 Output control module

1

1-2

1-2

1-2

10 Output modules

1

1-2

1-2

1-2

Voltage converter:

Voltage Converter 24V-12V 2A[a]

1

1

1

1

1

1

Voltage Converter 24V-12V 2A

1

1

1

1

1

1

Relay card:

Relay card SSF Series (PRO1)

1[b]

Relay card NOVA Series (15A and 25A-PRO2V3)

1[c]

Relay card NOVA Series (5A and 10A-PRO3)

1[d]

Lightning Protection:

T-SPD L

1

1

1

1

1

1

1

Power outage:

ECO mains failure alarm card[e]

1

1

1

1

1

1

1

[a] The card also has ground fault indication.

[b] Compatible with products that have PRO1 motherboards.

[c] Compatible with products that have PRO2v3 motherboards.

[d] Compatible with products that have PRO3 motherboards.

[e] All battery backups except ECO and PoE have alarms for mains interruptions and this card is then not needed.

Area of use

Power Supply -

Encapsulated power supplies

ECO

PoE

PoE M

NEO

NOVA

EN54

SINE UPS

Where:

Multi-apartment buildings, (apartments, apartment buildings, etc.)

*

*

*

*

*

*

*

Public buildings, (schools, hospitals, courts, municipal halls, museums, etc.).

*

*

*

*

*

*

*

*

Commercial properties, (shopping centers, arenas, shops, etc).

*

*

*

*

*

*

*

*

Industries, warehouses and offices.

*

*

*

*

*

*

*

*

Security classified areas (airports, ports, etc).

*

*

*

*

*

*

*

*

The product is used for:

Applications that require continuous power supply but not backup power.

*

Fire alarm system, certified according to EN54-4

*

Fire curtains

*

Door environments with redundancy

*

*

Property automation

*

*

*

*

*

Burglar alarm

*

*

Emergency lighting

*

Emergency opening of industrial gates and doors

*

Access system with monitoring, certified SSF1014

*

Pass system without supervision

*

*

*

*

*

PoE devices

*

*

Smoke hatches

*

Accessibility adaptation, (doors and other motorized applications).

*

Surveillance cameras

*

*

*

Can be customized?

Customer adaptations can be anything from the manufacture of products with a different brand to the development and manufacture of specially designed components / products according to the customer's specifications.

Power Supply -

Encapsulated power supplies

ECO

PoE

PoE M

NEO

NOVA

EN54

SINE UPS

Can be customized?

*

*

*

Customizations require MOQ, contact sales@milleteknik.se for more information.

About this information