SINUS UPS 200W S

Article Number: SM01U0011FP002B70
E-number: 5213620

230V, 200W UPS with a 7Ah battery.

The UPS has controlled charging that prevents batteries from overcharging and significantly extends their life.

  • A PICT output.
  • an emergency lighting exit;
  • LED for alarm indication.
  • Three cable penetrators.

Alarm (1-out):

  • power outage;
  • Incorrect charge voltage,
  • Aged Battery,
  • Unsupported UPS.

Mounting: Wall. Installation and Deployment: Fixed Installation. Battery types: Lead acid, AGM batteries. Fan-less: Yes Battery Boxes Connectable: No battery box connects to this UPS. Typical uses:

  • Emergency opening for doors and other passages mainly accessible.

*Controlled charging means that the batteries are charged at a lower charge voltage to reduce battery wear. This means that batteries are charged full (100%) more slowly. A 12 V, 7.2 battery will be fully charged at most with 30% of 1.2 Ah = 2.16 Ah. If you need a controlled upload time, this is available in our EN54 series.

Recommended environment

Security class (IP-klass)

Recommended mounting

Wall

Dimensioner (Höjd x Bredd x Djup)

230 x 216 x 85 mm

Net weight

Number of cable ports

3

Color

Built in cooling fan

No

Spänningsform

Single phase sine wave voltage

Max effect in operation

200 W

Max effect at start

1 kVA

Available charging current (A)

5 A

Voltage in (V)

230 – 240 VAC, 50-60 Hz

Power grid

Charger max 0.4 A + load

Current out

230 VAC

Rated power

200 W

Efficiency

Idle power values

approx.10 W

Fuses

T16A – fuse for power supply

Number of unsecured (load-) outputs

Deep discharge of battery occurs at

21 VDC

Battery type

12 V maintenance free AGM battery

Battery loading

I / U in accordance with DIN 41773 Current limits

Recommended battery

1 UPLUS 12 V, 7.2 Ah battery

Batteries included

Yes

Protection

Automatic fuse: batteries are fused., Current limiting, electric. Approx. 200% of rated capacity., Deep discharge protection: When battery pole voltage goes under 19 V, Optional: Residual current device: Can be installed on output (extra safety option in accordance with EN62040-1-1)., Overload protection: Disconnection of charging current in the event of overload 27.9 V., Short circuit protection: Shut down within 5 sec. in evet of major overload/short circuit in accordance with UPS EN62040-1-1standard. Automatic restart when power supply is returned.

Protection against

, , , ,

Self test

Battery discharge, Battery discharge: continual monitoring of battery charger, Inverter: Test load of UPS (corresponding rated power over internal test load) in order to check function and sufficient output voltage.

Alarm via

Changeover relay

Alarm functions

Alarm for (1 output): Power grid failure,, Faulty charge current , Old battery, Non functioning UPS

Number of alarm outputs

1 (total alarm outputs)

Tamper switch

No

Lockable enclosure

No

Number of optional cards that can be placed

No optional card mounting possible

In-stock article

No

Normal dlivery time

Guarantee period

2 years

Product meets requirements in accordance with

CE directive in accordance with:765/2008, EMC Directive 2014/30EU, Emission: EN61000-6-:2001, EN55022:1998:-A1:2000, A2:2003 Class B, EN61000-3-2:2001, Immunity: EN61000-6-2:2005, EN61000-4-2, -3, 4, -5, -6, -11, Low voltage directive: 2014/35/EU

Producer

Milleteknik AB

Country of origin

Not

All specifications subject to change in event of product changes or incorrect data