Min varukorg

Search
Close this search box.

NOVA 12V 10A FLX L

Article Number: FL01P30012P100
E-number: 5213649

Primary switched battery backup 12 V 10 (A) Amps with room for two 45 Ah batteries.

Nova series battery backup has high flexibility, advanced alarm features, long spare operating times, can handle high loads and has communication. NOVA battery packs have advanced controlled charging* that prevents batteries from being overcharged and significantly prolongs their life. The battery backup reads the attached load and recharges the batteries with the remaining power from the power supply. NOVA Battery Backups also perform battery tests to notify when batteries need to be replaced. To maintain certificates, UPLUS 10+ Design Life AGM batteries shall be used. NOVA has intelligent charging which means that when the batteries are fully charged, they will be put in electronically for standby mode for up to 20 days or when the battery voltage has reached 13.4 V / 26.7 V. By discharging the batteries controlled and recharging them cyclically (instead of not using them), the life of the batteries is extended by up to 50%. The batteries automatically connect in less than 50 microseconds, if needed. NOVA as 12 V is not certified. Mounting: NOVA can be mounted on wall or in 19″ racks, reversible brackets included. Installation and Deployment: Fixed Installation. Battery types: UPLUS 10+ Design Life AGM batteries. Battery boxes (sold separately): It is not possible to extend NOVA 12 V with more battery boxes. Typical uses:

  • Passes
  • Locking system
  • Alarm system

*Controlled charging means that the batteries are charged at a lower charge voltage to reduce battery wear. This means that batteries are charged full (100%) more slowly. A 12 V, 7.2 battery will be fully charged at most with 30% of 1.2 Ah = 2.16 Ah. If you need a controlled upload time, this is available in our EN54 series.

Recommended environment

Security class (IP-klass)

Recommended mounting

19" rack, Wall

Height units

10RU

Dimensioner (Höjd x Bredd x Djup)

444 x 437 x 212 mm

Net weight

Number of cable ports

4

Color

Built in cooling fan

Yes

Voltage in (V)

230 – 240 VAC, 50-60 Hz

Current out

13.6 VDC (12 V), 27.3 VDC (24 V)

Max current

Available charging current (A)

Dependent upon power outlet, though max 6 A

Rated power

150 W

Ripple i normal mode

200 mVp-p

Efficiency

heat generation at 50% / 80% of rated power

8.4 W / 13.5 W

Current in (A)

1.7 A

Number of unsecured (load-) outputs

Type of fuse / ouput

2 F10A (glass)

Deep discharge of battery occurs at

10,5 VDC

Battery type

12 V maintenance free AGM battery

Battery capacity

Recommended battery

2 UPLUS 12 V, 45 Ah batteries

Batteries included

No

Protection against

, , , ,

Alarm via

Changeover relay / RS485. Option: RS232, TCP/IP

Alarm functions

Battery disconnected (10 sec), Charger error overvoltage, Charger error undervoltage, Delayed power grid failure alarm (10 sec), Fuse failure (buzzer alarm, alarm output 2), Low battery voltage, Low system voltage, Old battery, Tampering

Number of alarm outputs

4

Support for communication via

RS-232, RS-485, RS-485/OSDP, TCP/IP

Information via protocol

Alarm for high / low temperature, Alarm from temperature sensor, All standard alarm functions, Fan error, Forced battery test, Highest and lowest battery voltage since start, Highest and lowest temperature since start, Minimum / Max / Average temperature the latest hour / 72 hours, Minimum / Max / Average voltage the latest / 1 hour / 24 hours / 72 hours, Minimum / Max / Average voltage the latest 1 hour / 72 hours, Operational time in event of power outage, Possibility to set alarm levels

Tamper switch

Yes

Lockable enclosure

Yes, two keys included.

Number of optional cards that can be placed

Three L-module option

In-stock article

No

Normal dlivery time

Guarantee period

5 years (special warranty conditions apply)

Warranty conditions 5 year warranty

Average load shall not exceed 80 % of power supply's rated capacity-, Battery backup shall be used together with UPLUS 10+ Design Life batteries., Surrounding temperature shall not exceed 32°C., The fan shall be cleaned annually and replaced if needed.

Product meets requirements in accordance with

CE directive in accordance with:765/2008, EMC Directive 2014/30EU, Emission: EN61000-6-:2001, EN55022:1998:-A1:2000, A2:2003 Class B, EN61000-3-2:2001, Immunity: EN61000-6-2:2005, EN61000-4-2, -3, 4, -5, -6, -11. SS-EN 50 130-4:2011 Edition 2 & SSF1014 Alarm class 1-4 (Burgler alarm)., Low voltage directive: 2014/35/EU

Producer

Milleteknik AB

Country of origin

Not

All specifications subject to change in event of product changes or incorrect data

Product Files

Support

Accessories

You may also like…